Lỗi CANON IR 2525


ERROR CODE - E0----------E3

Code
Sub
Code
Description
E000
0001
Fixing temperature abnormal rise
The temperature detected by the main thermistor does not rise to the specified value during startup control.
E001
0000
Fixing unit temperature rise detection
The reading of the main thermistor is 250 deg C or more continuously for 200 msec.
0001
Fixing unit temperature rise detection
The hardware circuit detects overheating of the main or sub thermistor for 200 msec.
0002
Fixing unit temperature rise detection
The reading of the sub thermistor is 295 deg C or more continuously for 200 msec.
E002
0000
Fixing unit temperature insufficient rise
1.The reading of the main thermistor is less than 115 deg C continuously for 400 msec 1.3 sec after it has indicated 100 deg C.
2.The reading of the main thermistor is less than 150 deg C continuously for 400 msec 1.3 sec after it has indicated 140 deg C.
E003
0000
Low fixing temperature detection after standby
The reading of the main thermistor is less than 140 deg C continuously for 400 msec or more.
E004
0000
Thermistor disconnection detection error
When disconnection is detected with connector (J214) for 30 sec continuously.
E010
0001
Unstable rotation of the Main Motor (M1)
Detection is executed every 100 msec after the start of motor rotation; however, the drive detection signal is absent for 2 sec.
0002
Unstable rotation of the Main Motor (M1)
During motor rotation, detection is executed every 100 msec; however, the drive signal is absent 5 times in sequence.
E014
0001
Unstable rotation of the Fixing Motor (M2)
Detection is executed every 100 msec after the start of motor rotation; however, the drive detection signal is absent for 2 sec.
0002
Unstable rotation of the Fixing Motor (M2)
During motor rotation, detection is executed every 100 msec; however, the drive signal is absent 5 times in sequence.
E019
0000
Error in Waste Toner Sensor (S17)
Warning when the sensor goes on for 2000 consecutive sheets, and error when the sensor goes on for 100 consecutive sheets. 
* Error occurs after the delivery if a paper in passage exists.
E020
0000
The path between the sub hopper and the developing assembly is clogged with toner.
The Developing Assembly Toner Sensor (TS1) detects the absence of toner,while the Sub Hopper Toner Sensor (TS2) detects the presence of toner. With the Developing Cylinder Clutch (CL3) turned on, the hopper feedscrew motor (M7) is rotated for 1 sec intermittently 194 times; still, theDeveloping Assembly Toner Sensor (TS1) does not detect the presence of toner. 
* Error occurs after the delivery if a paper in passage exists.
E024
0000
The connector (J207) of Developing Assembly Toner Sensor (TS1) is disconnected.
The Developing Assembly Toner Sensor (TS1) connection detection signal is absent for 100 msec 10 times in sequence. * Error occurs after the delivery if a paper in passage exists.
0001
The Developing Assembly Toner Sensor (TS1) is disconnected
.<At LOW SPEED> 
- The developing assembly toner sensor (TS1) ON counter is checked every 2.5 seconds, and the counter increments 1 count every 25 times when the sensor goes on, and 300 counts are reached.
<At HIGH SPEED>
- The developing assembly toner sensor (TS1) ON counter is checked every 1.5 seconds, and the counter increments 1 count every 15 times when the sensor goes on, and 300 counts are reached.
E025
0000
The connector (J207) of Sub Hopper Toner Sensor (TS2) is disconnected.
The Sub Hopper Toner Sensor (TS2) connection detection signal is absent for 100 msec 10 times in sequence. 
* Error occurs after the delivery if a paper in passage exists.
0001
Failure of the Bottle Motor (M6)
The bottle motor (M6) is unlocked when it goes on for 12 consecutive times at 0.1 sec. intervals. 
* Error occurs after the delivery if a paper in passage exists.
E110
0001
Failure of the Scanner Motor (M21)
The Scanner Motor (M21) speed lock signal does not indicate a locked state a specific period of time after the Scanner Motor (M21) has been started. 
* The same condition is detected after the error retry is performed.
0002
Failure of the Scanner Motor (M21)
The speed lock signal indicates a deviation 10 times in sequence at intervals of 100 msec after the signal has indicated a locked state. 
* The same condition is detected after the error retry is performed.
0003
Failure of the Scanner Motor (M21)
The scanner motor (M21) speed lock signal does not indicate a locked state for 6.5 sec. after a switchover is made from low to normal speed or for 8 sec. after a switchover is made from normal to low speed. 
* The same condition is detected after the error retry is performed.
E196
0000
Error in EEPROM access
20 retries failed after error occurred during communication with EEPROM.
* Error occurs after the delivery if a paper in passage exists.
E197
0000
Error in communication of Laser Driver PCB (PCB14)
Communication error 1 with image PCB
0001
Error in communication of Laser Driver PCB (PCB14)
Communication error 2 with image PCB
E202
0000
There is an error in the detection of the CIS home position.
1.The attempt to detect the home position fails when the CIS is moved forward. 
2.The attempt to detect the home position fails when the CIS is moved back.
E240
0000
Error in controller communication
The serial communication error such as parity error or overrun error is constantly detected.
0001
Error in controller communication
The serial communication error such as parity error or overrun error is detected while printing.
E246
0000
Writing to the counter PCB (FRAM) failed
E247
0000
Mismatched checksum between the Flash Rom and the FRAM
E261
0000
Error in Zero Cross
Zero Cross failed to be detected for 500ms or more while the relay was ON. 
* The same condition is detected after the error retry is performed.
E350
0000
SOFT-ID PCB error
E354
0000
Mismatched serial number for the SOFT-ID PCB
E355
0000
Mismatched serial number between the SOFT-ID, the Flash Rom and the FRAM

0004
System information error

0005
System information error